CKZSF - KODAK PHOTOLIFE PHOTO/ELECTRONIC BATTERY SIZE: IEC-MR9,KX625

  • MSDS: CKZSF
  • Manufacturer: EASTMAN KODAK COMPANY
  • Product Name: KODAK PHOTOLIFE PHOTO/ELECTRONIC BATTERY SIZE: IEC-MR9,KX625
  • National Stock Number: 6135-00-900-2139
Product Identification

Product ID:KODAK PHOTOLIFE PHOTO/ELECTRONIC BATTERY SIZE: IEC-MR9,KX625
MSDS Date:10/30/1990
FSC:6135
NIIN:00-900-2139
Status Code:A
MSDS Number: CKZSF

Responsible Party
EASTMAN KODAK COMPANY
343 STATE STREET
ROCHESTER, NY 14650
US

Emergency Phone: 7167225151

Info Phone: 716-722-5151

Cage: 19139

Contractor
EASTMAN KODAK CO GOVERNMENT MARKETS CONTRACTS
ROCHESTER, NY 14650-1115 US

Telephone: 716-722-5151/(800) 242-2424

Cage: 19139

Ingredients

43%)

RTECS: PS1006506

Fraction By Weight: 4.0%


MERCURIC OXIDE

RTECS: MD1007952

Fraction By Weight: 33.6%


ZINC

CAS: 7440-66-6

RTECS: ZG8600000

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


MERCURY

CAS: 7439-97-6

RTECS: OV4550000

OSHA PEL see Table Z-2

ACGIH TLV: 0.025 MG/M3

EPA Report Quantity: 1 LB

DOT Report Quantity: 1 LB

Hazards

Medical Cond Aggravated by Exposure:

First Aid

First Aid:ELECTROLYTE CONTACT: SKIN: IMMEDIATELY FLUSH WITH PLENTY OF
WATER FOR AT LEAST 15
MINUTES. IF SYMPTOMS ARE PRESENT AFTER FLUSHING, GET MEDICAL ATTENTION.
EYES:IMMEDIATELY FLUSH WITH PLENTY OF WATE R FOR AT LEAST 15
MINUTES AND GET MEDICAL
ATTENTION. BATTERY INGESTION: OBTAIN IMMEDIATE MEDICAL ATTENTION.

Fire Fighting

Extinguishing Media:USE AN EXTINGUISHING MEDIUM APPROPRIATE FOR THE
SURROUNDING FIRE.
Fire Fighting Procedures:USE A POSITIVE PRESSURE SELF-CONTAINED
BREATHING APPARATUS IF BATTERIES ARE INVOLVED IN A FIRE. FULL
PROTECTIVE CLOTHING IS NECESSARY.
Unusual Fire/Explosion Hazard:BATTERIES MAY RELEASE TOXIC VAPORS AND/OR
IRRITATING FUMES IF EXPOSED TO FIRE OR HIGH TEMPERATURES.
BATTERIES MAY VENT AND/OR EXPLODE IF EXPOSED TO EXCESSIVE HEAT OR
FIRE.

Handling

Handling and Storage Precautions:DO NOT STORE BATTERIES IN A MANNER
THAT ALLOWS TERMNLS TO SHORT CIRCUIT. STORE
BATTERIES IN A COOL (BELOW 70F), DRY AREA THAT IS SUBJCT TO LITTLE TEMP
CHANGE. DO NOT
PLACE NEAR HEATING EQPMENT, NOR EXPSE TO DIRCT SUNLIGHT FOR LONG
PERIODS. ELEVATED
TEMPS CAN RESLT IN REDCED BATTERY SERVCE LIFE.

Exposure Controls

Supplemental Safety and Health

Chemical Properties

HCC:N1
Appearance and Odor:9-VOLT BATTERY, RECTANGULAR WITH ROUNDED CORNERS,
SNAP-ON TERMINALS.

Stability

Stability Indicator/Materials to Avoid:YES
IF HYDROGEN GAS IS PRESENT, SHORT CIRCUITS, HIGH TEMPERATURE, OR STATIC
SPARKS CAN CAUSE AN IGNITION.
Stability Condition to Avoid:HIGH TEMPERATURE, ENCAPSULATION, PROLONGED
SHORT CIRCUITS. DO NOT OBSTRUCT SAFETY RELEASE VENTS ON BATTERIES.
Hazardous Decomposition Products:HYDROGEN, POTASSIUM HYDROXIDE.

Disposal

Waste Disposal Methods:CONSULT LOCAL, STATE AND FEDERAL ENVIRONMENTAL
PROTECTION AUTHORITIES FOR THE
MOST CURRENT REGULATIONS REGARDING DISPOSAL OF BATTERIES. DO NOT
INCINERATE OR
EXPOSE BATTERIES TO FIRE.

Toxicology

Toxicological Information:BATTERY CHARGING: THESE BATTERIES ARE NOT
DESIGNED TO BE RECHARGED. CHARGING A BATTERY MAY RESULT IN
ELECTROLYTE LEAKAGE AND/OR EXPLOSION. BATTERY DISASSEMBLY: NEVER
DISASSEMBLE A BATTERY. SHOULD A BATTERY UNINTENTIONALLY BE
CRUSHED THUS RELEASING ITS CONTENTS, RUBBER GLOVES MUST BE USED TO
HANDLE ALL BATTERY COMPONENTS. IN THE EVENT OF SKIN OR EYE
EXPOSURE TO THE ELECTROLYTE REFER TO FIRST A ID INFORMATION. *

Other Information

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.

Ecology

Ecological:*MORE THAN A MOMENTARY SHORT CIRCUIT WILL GENERALLY REDUCE
THE BATTERY SERVICE LIFE. EXTENDED SHORT CIRCIUTING CREATES HIGH
TEMPERATURES IN THE CELL. HIGH TEMPERATURES CAN CAUSE SKIN BURNS
AND CAUSE THE CELL TO VENT OR EXPLODE. **

Transport

Transport Information:***THE USE OF OLD AND NEW BATTERIES OR BATTERIES
OF VARYING SIZES AND TYPES IN THE SAME BATTERY ASSEMBLY SHOULD BE
AVOIDED. THE BATTERIES ELECTRICAL CHARACTERISTICS AND CAPABILITIES
VARY AND DAMAGE M AY RESULT TO THE BATTERIES OR ELECTRICAL
EQUIPMENT. USE NICKEL PLATED STEEL (OR STAINLESS STEEL) FOR POWER
TERMINAL CONTACTS. DO NOT DIRECTLY SOLDER TO THE BATTERY. MAY
CAUSE VENTING AND/OR EXPLOSI ON. ****

Regulatory

SARA Title III Information:THE USE OF OLD AND NEW BATTERIES OR
BATTERIES OF VARYING SIZES AND TYPES IN THE SAME BATTERY ASSEMBLY
SHOULD BE AVOIDED. THE BATTERIES ELECTRICAL CHARACTERISTICS AND
CAPABILITIES VARY AND DAMAGE MAY RESULT TO THE BATTERIES OR
ELECTRICAL EQUIPMENT. USE NICKEL PLATED STEEL (OR STAINLESS STEEL)
FOR POWER TERMINAL CONTACTS. DO NOT DIRECTLY SOLDER TO THE
BATTERY. MAY CAUSE VENTING AND/OR EXPLOSION. AVOID ENCASING
BATTERIES IN AIRTIGHT COMPARTMENTS. FLAMMABLE HYDROGEN GAS,
NORMALLY GENERATED, CAN FORM EXPLOSIVE MIXTURES. PROVISIONS FOR
VENTING MUST BE PROVIDED. NEVER COMPLETELY ENCAPSULATE A BATTERY.
TO DO SO WILL INHIBIT THE SA
State Regulatory Information: